Item |
Specifications |
Model (DEX20□H□A□□□G) |
007 |
015 |
022 |
040 |
055 |
075 |
110 |
150 |
185 |
220 |
300 |
370 |
450 |
550 |
750 |
Applicable motor power (kW) |
0.75 |
1.5 |
2.2 |
4.0 |
5.5 |
7.5 |
11 |
15 |
18.5 |
22 |
30 |
37 |
45 |
55 |
75 |
Output |
Voltage (V) |
3-phase 0 ~ rated input voltage |
Rated current (A) |
2.5 |
3.8 |
5.5 |
9 |
13 |
17 |
24 |
30 |
39 |
45 |
60 |
75 |
91 |
112 |
150 |
Overload capacity |
150% for 1 minute, 180% for 10 seconds, 200% for 0.5 seconds every 10 minutes (inverse time characteristics) |
Input |
Rated voltage / frequency |
3-phase 380V ~ 480V; 50Hz/60Hz Hz |
Voltage tolerance range |
323V~528V;Voltage imbalance :≤3% ;Frequency fluctuation tolerance :±5% |
Rated current (A) |
3.5 |
6.2 |
9.2 |
14.9 |
21.5 |
27.9 |
39 |
50.3 |
60 |
69.3 |
86 |
104 |
124 |
150 |
201 |
Braking unit |
Standard internal configuration |
Optional internal configuration |
Protection level |
IP20 |
Cooling method |
Auto-cooling |
Forced air cooling |
Model (DEX20□HXA□□□□G) |
900 |
1100 |
1320 |
1600 |
2000 |
2200 |
2800 |
3150 |
3550 |
4000 |
|
|
|
|
|
Applicable motor power (kW) |
90 |
110 |
132 |
160 |
200 |
220 |
280 |
315 |
355 |
400 |
|
|
|
|
|
Output |
Voltage (V) |
3-phase 0 ~ rated input voltage |
Rated current (A) |
176 |
210 |
253 |
304 |
380 |
426 |
520 |
585 |
650 |
740 |
|
|
|
|
|
Overload capacity |
150% for 1 minute, 180% for 10 seconds, 200% for 0.5 seconds every 10 minutes (inverse time characteristics) |
Input |
Rated voltage / frequency |
3-phase 380V ~ 480V; 50Hz/60Hz |
Voltage tolerance range |
323V~528V;Voltage imbalance:≤3% ;Frequency fluctuation tolerance:±5% |
Rated current (A) |
160* |
196* |
232* |
282* |
352* |
385* |
491* |
552* |
624* |
704* |
|
|
|
|
|
Braking unit |
Requiring an external braking unit |
Protection level |
IP20 |
Cooling method |
Forced air cooling |